Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Cardiol ; 214: 105-108, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38160924

RESUMO

The natural history and treatment of an aortic cusp aneurysm with or without rupture because of native aortic valve infective endocarditis (NAV-IE) have not been well defined. This may explain why current guidelines for the management of valvular heart disease do not include this complication as an indication for surgical aortic valve replacement or repair or transcatheter aortic valve replacement (TAVR). We describe herein the first case of a man aged 76 years with multiple co-morbidities with a NAV-IE associated large left coronary cusp aneurysm with subsequent rupture and consequent severe aortic regurgitation and heart failure for which he underwent an off-label successful TAVR. This patient's scenario suggests that a cusp aneurysm because of NAV-IE poses a high risk for subsequent rupture, severe aortic regurgitation, and heart failure. In conclusion, TAVR may be a reasonable alternative to high-risk surgical aortic valve replacement in patients with NAV-IE associated cusp aneurysms with or without but impending rupture.


Assuntos
Aneurisma , Insuficiência da Valva Aórtica , Endocardite Bacteriana , Endocardite , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico , Endocardite/complicações , Endocardite/diagnóstico , Endocardite/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência Cardíaca/complicações , Aneurisma/complicações
2.
Cardiovasc Revasc Med ; 30: 40-46, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33046416

RESUMO

OBJECTIVE: To evaluate the feasibility of using the DyeVert™ Plus EZ Contrast Reduction System in optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) procedures and to assess OCT image quality. BACKGROUND: OCT is employed as a powerful intravascular imaging modality; however, it requires blood displacement via contrast injection during image acquisition, thereby posing risk of nephrotoxicity. The DyeVert System is designed to reduce and facilitate monitoring of contrast media volume (CMV) delivered, without diminishing image quality. METHODS: We conducted a prospective clinical feasibility study to determine whether the DyeVert System is non-inferior to manual contrast injection in reducing CMV without lessening image quality during OCT-guided PCI procedures. Eligible participants were ≥ 18 years of age, indicated for coronary OCT, and able to provide informed consent. The primary endpoint was CMV saved during angiography; the secondary endpoint was image quality as evaluated by operators in real time and by an independent core laboratory that also assessed images from a control group that underwent comparable procedures performed without the DyeVert System. RESULTS: Fourteen participants underwent 15 coronary OCT procedures using the DyeVert System. Mean age among participants was 67 ± 11 years, and 11 (78%) were male. Mean eGFR was 71 ± 20 mL/min/1.73m2. Mean attempted CMV administration was 342.01 ± 129.8 mL; mean CMV delivered was 216.21 ± 88.87 mL, representing CMV savings of 37.5 ± 5.3%. Results from quantified OCT analysis suggest that the clear region of interest (ROI) in the DyeVert group was non-inferior (p < .0001) to the control group. There were no device-related adverse events. CONCLUSIONS: The DyeVert™ Plus EZ Contrast Reduction System reduced CMV and preserved an image quality that was non-inferior to OCT-guided PCI procedures without using the contrast reducing device.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Idoso , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Tomografia de Coerência Óptica , Resultado do Tratamento
3.
ASAIO J ; 65(1): 21-28, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29489461

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has been used for refractory cardiogenic shock; however, it is associated with increased left ventricular afterload. Outcomes associated with the combination of a percutaneous left ventricular assist device (Impella) and VA-ECMO remains largely unknown. We retrospectively reviewed patients treated for refractory cardiogenic shock with VA-ECMO (2014-2016). The primary outcome was all-cause mortality within 30 days of VA-ECMO implantation. Secondary outcomes included duration of support, stroke, major bleeding, hemolysis, inotropic score, and cardiac recovery. Outcomes were compared between the VA-ECMO cohort and VA-ECMO + Impella (ECPELLA cohort). Sixty-six patients were identified: 36 VA-ECMO and 30 ECPELLA. Fifty-eight percent of VA-ECMO patients (n = 21) had surgical venting, as compared to 100% of the ECPELLA cohort (n = 30) which had Impella (±surgical vent). Both cohorts demonstrated relatively similar baseline characteristics except for higher incidence of ST-elevation myocardial infarction (STEMI) and percutaneous coronary intervention (PCI) in the ECPELLA cohort. Thirty-day all-cause mortality was significantly lower in the ECPELLA cohort (57% vs. 78%; hazard ratio [HR] 0.51 [0.28-0.94], log rank p = 0.02), and this difference remained intact after correcting for STEMI and PCI. No difference between secondary outcomes was observed, except for the inotrope score which was greater in VA-ECMO group by day 2 (11 vs. 0; p = 0.001). In the largest US-based retrospective study, the addition of Impella to VA-ECMO for patients with refractory cardiogenic shock was associated with lower all-cause 30 day mortality, lower inotrope use, and comparable safety profiles as compared with VA-ECMO alone.


Assuntos
Terapia Combinada/métodos , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Choque Cardiogênico/terapia , Idoso , Terapia Combinada/mortalidade , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Choque Cardiogênico/mortalidade
5.
Catheter Cardiovasc Interv ; 92(4): 757-765, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29171682

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgical aortic valve replacement (SAVR) for patients with severe symptomatic aortic stenosis (AS) who are at intermediate and high risk for surgery. Commercial use of TAVR has expanded to patients with end stage renal disease (ESRD). OBJECTIVES: Compare in-hospital outcomes of TAVR versus SAVR in ESRD patients requiring hemodialysis (HD). METHODS: ESRD patients on HD undergoing TAVR (n = 328) or SAVR (n = 697) between 2012 and 2014 were identified in the National Inpatient Sample (NIS). Propensity-score matching method was used to minimize selection bias. Baseline characteristics and in-hospital outcomes were compared. RESULTS: TAVR patients were older (75.3 vs. 61.6 years, P < 0.001) and had more comorbidities, including congestive heart failure (16.2% vs. 7.5%), diabetes mellitus (28.4% vs. 22.5%), chronic lung disease (27.7% vs. 20.4%), and peripheral vascular disease (35.1% vs. 21.2%). Propensity-score matching yielded 175 pairs of patients matched on 30 baseline covariates. Overall in-hospital mortality was high (9.9%) and similar between TAVR and SAVR (8% vs. 10.3%, P = 0.58). TAVR was associated with shorter length of stay (LOS) (8 vs. 14 days, P < 0.001), lower hospitalization cost ($276,448 vs. $364,280, P = 0.01), lower in-hospital complications (60.6% vs. 76%, P = 0.003), and higher rate of home discharge (31.4% vs. 17.7%, P = 0.004) compared with SAVR. CONCLUSIONS: Regardless of treatment modality, patients with AS on HD have high in-hospital mortality. TAVR and SAVR have comparable in-hospital mortality in this population. However, TAVR is associated with shorter LOS, lower hospitalization costs, lower in-hospital complications, and higher rates of home discharge.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Falência Renal Crônica/terapia , Diálise Renal , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/mortalidade , Análise Custo-Benefício , Bases de Dados Factuais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/economia , Implante de Prótese de Valva Cardíaca/mortalidade , Custos Hospitalares , Mortalidade Hospitalar , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/economia , Falência Renal Crônica/mortalidade , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Complicações Pós-Operatórias/mortalidade , Diálise Renal/efeitos adversos , Diálise Renal/economia , Diálise Renal/mortalidade , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/economia , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
6.
Catheter Cardiovasc Interv ; 88(2): E45-51, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26526037

RESUMO

OBJECTIVES: The aim of current study is to assess the near term impact of percutaneous ventricular restoration therapy (PVR), Parachute(®) on mitral valve (MV) geometry by cardiac computed tomography (CCT). BACKGROUND: Recent data demonstrates the feasibility of PVR for treatment of post anterior myocardial infarction (MI) heart failure. Little is known, however, about the interaction of the device and left ventricular structures, particularly the MV apparatus. METHODS: This is a retrospective Core Laboratory analysis of Parachute Trials' CCT data. Patients with paired (before and after Parachute implant) CCT acquisitions were included into analysis. MV geometric parameters were measured. RESULTS: Thirty-three patients were included in the analysis. The mean time of follow-up CCT post procedure was 188 ± 52 days. There were significant reduction in tenting height (A1P1: -1.70 ± 1.89 mm, -17.40 ± 20.20%; A2P2: -1.43 ± 1.89 mm, -12.10 ± 15.00%; A3P3: -1.54 ± 1.58 mm, -15.50 ± 15.20%, P < 0.001), tenting volume (-0.93 ± 0.60 mm3, -22.00 ± 11.40%, P < 0.001), systolic interpapillary muscle distance (-2.22 ± 2.11 mm, -7.51 ± 7.23%, P < 0.001) and diastolic interpapillary muscle distance (-3.14 ± 2.20 mm, -8.46 ± 5.73%, P < 0.001) post PVR. CONCLUSIONS: In post anterior MI heart failure patients, PVR has favorable near term impact on MV geometry as assessed by CCT. © 2015 Wiley Periodicals, Inc.


Assuntos
Infarto Miocárdico de Parede Anterior/terapia , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Infarto Miocárdico de Parede Anterior/diagnóstico por imagem , Infarto Miocárdico de Parede Anterior/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ensaios Clínicos como Assunto , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
J Neuroeng Rehabil ; 3: 21, 2006 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-16970818

RESUMO

BACKGROUND: There is currently a paucity of devices available for continuous, long-term monitoring of human joint motion. Non-invasive, inexpensive devices capable of recording human activity and joint motion have many applications for medical research. Such a device could be used to quantify range of motion outside the gait laboratory. The purpose of this study was to test the accuracy of the modified Intelligent Device for Energy Expenditure and Activity (IDEEA) in measuring knee flexion angles, to detect different physical activities, and to quantify how often healthy subjects use deep knee flexion in the ambulatory setting. METHODS: We compared Biomotion Laboratory (BML) "gold standard" data to simultaneous IDEEA measures of knee motion and gait, step up/down, and stair descent in 5 healthy subjects. In addition, we used a series of choreographed physical activities outside the BML to confirm the IDEEA's ability to accurately measure 7 commonly-performed physical activities. Subjects then continued data collection during ordinary activities outside the gait laboratory. RESULTS: Pooled correlations between the BML and IDEEA knee flexion angles were .97 +/- .03 for step up/down, .98 +/- .02 for stair descent, and .98 +/- .01 for gait. In the BML protocol, the IDEEA accurately identified gait, but was less accurate in identifying step up/down and stair descent. During sampling outside the BML, the IDEEA accurately detected walking, running, stair ascent, stair descent, standing, lying, and sitting. On average, subjects flexed their knees >120 degrees for 0.17% of their data collection periods outside the BML. CONCLUSION: The modified IDEEA system is a useful clinical tool for evaluating knee motion and multiple physical activities in the ambulatory setting. These five healthy subjects rarely flexed their knees >120 degrees.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...